How to Read a Servo Motor Torque-Speed Curve Before Selecting a Motor
Choosing a servo motor by rated power alone can be misleading.
Two servo motors may both be rated at 400 W, yet behave very differently once the machine begins accelerating, running at high speed or repeating short positioning cycles.
One of the most useful tools for understanding this difference is the torque-speed curve.
For an OEM engineer or equipment buyer, you do not need to become a motor-design specialist to use this chart. You only need to understand what the main lines and operating regions mean, and how they relate to the movement of your machine.
What Does a Servo Motor Torque-Speed Curve Show?
A torque-speed curve shows how much torque a motor can deliver at different rotational speeds.
The horizontal axis normally represents speed in rpm, while the vertical axis represents torque in N·m.
Most industrial servo-motor curves also distinguish between two important operating limits: rated or continuous torque, and peak or intermittent torque.
That distinction is more useful than simply knowing the motor's rated power.
A machine may spend most of its operating cycle at moderate torque but briefly require much higher torque during acceleration. The torque-speed curve shows whether the motor can handle both conditions.
Jiangnan Electric's current servo catalogue uses this format across multiple product families. For example, the 20E Series curves separately identify rated torque, peak torque, continuous-duty operation and intermittent-duty operation.
Rated Torque: What the Motor Can Deliver Continuously
Rated torque is the torque the motor is designed to provide continuously under the specified operating and thermal conditions.
If a machine requires 1.0 N·m for most of an eight-hour production shift, this continuous demand is usually more important than a very high peak torque number.
Operating continuously above the rated region can cause excessive temperature rise even if the motor is mechanically capable of producing the torque for a short period.
That is why servo selection should distinguish between how much torque the machine needs continuously and how much torque it needs briefly.
This also explains why a motor should not be selected simply because its peak torque looks impressive.
Peak Torque: Useful for Acceleration, Not Continuous Operation
Servo motors are often designed to produce considerably more torque for short periods than they can provide continuously.
This additional torque is useful during acceleration, deceleration, rapid direction changes, indexing and short overload events.
The duration and frequency of these events matter.
If an axis repeatedly requires peak torque for too much of the machine cycle, the motor may overheat even though each individual acceleration appears to fall inside the peak-torque envelope.
A proper selection therefore considers both the magnitude of the peak torque and the duty cycle.
Jiangnan's catalogue shows this clearly. The 25D Series characteristic curves separate the Continuous Duty Region from the Intermittent Duty Region rather than presenting a single maximum torque number.
Why Torque Usually Changes as Speed Increases
At lower and moderate speeds, many servo motors can maintain relatively stable torque over part of their operating range.
As speed increases, however, the available torque may begin to decrease.
This happens because the motor and servo drive are working within electrical limits such as available voltage and current. At higher rotational speeds, the voltage required to maintain the same torque becomes more difficult to provide.
The exact shape depends on the motor and drive combination.
This is why the question "What is the maximum speed?" is not enough.
A better question is: "How much torque is available at the speed my machine actually needs?"
A motor may be capable of reaching 5,000 rpm, but that does not necessarily mean it can provide rated torque at 5,000 rpm.

Rated Speed and Maximum Speed Are Different
This distinction is particularly important when reading servo specifications.
Rated speed is normally the reference operating speed associated with the motor's rated performance.
Maximum speed is the highest permitted or achievable speed under specified conditions.
The two should not be treated as interchangeable.
For example, Jiangnan's 40B Series includes a 0.1 kW configuration with a rated speed of 3,000 rpm and a maximum speed of 5,000 rpm. The same product platform lists 0.32 N·m rated torque and up to 0.96 N·m peak torque for the relevant configuration.
This does not mean the motor delivers 0.96 N·m continuously at 5,000 rpm.
The actual allowable operating point must be read from the motor's torque-speed envelope.
That is exactly why the curve matters.
Continuous Duty Region vs Intermittent Duty Region
A useful way to read a servo curve is to imagine two boundaries.
The first boundary defines the region where the motor can operate continuously.
The second, higher boundary defines short-term operation.
Your normal operating points should generally remain within the continuous-duty region.
Short acceleration or deceleration events may extend into the intermittent region, provided the duration and duty cycle remain within the motor and drive limits.
If the machine spends most of its cycle in the intermittent area, the motor is probably too small for the application.
This is one of the most common mistakes that can occur when a motor is selected from peak torque alone.
A Simple Machine Example
Consider an indexing mechanism on a packaging machine.
During one cycle, the axis might start from zero speed, accelerate rapidly, move at constant speed, decelerate, stop for product processing, then repeat.
The motor may require only modest torque while moving at constant speed.
During acceleration, however, the required torque can increase sharply because the motor must accelerate both its own rotor and the mechanical load.
The correct motor therefore needs enough continuous torque for normal operation and enough peak torque for acceleration.
If the production rate increases later, the acceleration time may become shorter.
That can increase the required peak torque even though the mechanical load has not changed.
This is why machine cycle time should be part of servo-motor selection.
Do Not Read the Curve Without Considering Load Inertia
The torque-speed curve tells you what the motor can provide.
It does not tell you how much torque your machine requires.
That requires information about the load.
A motor has to accelerate its own rotor plus the load reflected back to the motor shaft.
The required acceleration torque depends on inertia and angular acceleration.
A heavy but slowly changing load may require less dynamic torque than a lighter mechanism that must accelerate extremely quickly.
Gearboxes, ball screws, belts and pulleys also change the relationship between motor speed, load speed, torque and reflected inertia.
The torque-speed curve should therefore be used together with the machine's motion profile rather than as a standalone specification.
Why the Servo Drive Matters
A torque-speed curve should also be read in the context of the servo drive used to generate it.
The servo drive supplies current and voltage to the motor.
Peak motor torque normally requires higher current, while higher-speed operation places greater demands on the available drive voltage.
Changing the drive can therefore affect the usable operating envelope.
When replacing a servo motor, checking only the mechanical dimensions is not sufficient.
The existing drive voltage, current capacity, encoder compatibility and control configuration should also be reviewed.
Jiangnan's current servo portfolio includes both low-voltage and higher-voltage platforms. The catalogue, for example, identifies B Series low-inertia products around a 48 V platform, while A Series products cover 220-380 V configurations.

How Jiangnan Presents Torque-Speed Data
Jiangnan Electric's current servo catalogue provides torque-speed characteristic curves for multiple compact and industrial servo families.
The 20E Series shows separate curves for 10 W, 20 W and 30 W versions. Each identifies rated torque, peak torque and the continuous and intermittent operating regions.
The 25D Series uses the same approach across 11 W, 22 W, 33 W and 50 W configurations.
For larger applications, the 60A Series catalogue similarly provides individual torque-speed curves for 200 W, 400 W and 600 W versions, again separating continuous operation from short-duration peak operation.
This consistency is useful for OEM customers because it allows different motor sizes to be compared using the same engineering logic.
Jiangnan's current website also lists servo products across multiple frame sizes and inertia classes, including compact 20E and 25E motors as well as 40, 60, 80 and larger-frame permanent-magnet servo families.
What Should You Check Before Choosing a Motor from the Curve?
For most OEM projects, the following information is enough to begin a meaningful selection:
- normal operating torque and speed;
- maximum required torque;
- maximum operating speed;
- acceleration and deceleration time;
- load inertia or mechanical drawing;
- gearbox or transmission ratio;
- cycle time;
- drive voltage and current capacity;
- encoder requirement;
- mounting and shaft dimensions.
The important point is that these values describe the machine, not just the motor you want to replace.
If an existing servo motor already works reasonably well, its nameplate and torque-speed data can also provide a useful reference.
Bigger Is Not Always Better
It may seem safer to select a much larger servo motor.
That can solve some torque problems, but oversized motors also bring disadvantages.
A larger motor can increase rotor inertia, physical size, cost and required drive capacity.
In a highly dynamic axis, unnecessary motor inertia can actually make acceleration more difficult.
A better approach is to select a motor whose continuous and peak operating regions properly cover the real machine cycle with an appropriate engineering margin.
This normally produces a more balanced servo system than simply choosing the next available power rating.
Use the Curve to Check the Real Operating Point
The most useful way to read a torque-speed curve is not to ask: "What is the maximum torque?"
Instead, ask: "At the speed my machine requires, can this motor provide the required torque, and can it do so for the required length of time?"
That question connects the motor data directly to the machine.
For an OEM project, the normal operating points should remain within the continuous region, while short acceleration and deceleration events may use the intermittent region when permitted by the motor and drive specifications.
Once torque, speed, duty cycle and inertia are considered together, the torque-speed curve becomes one of the most practical tools for selecting a servo motor.
For new designs and replacement projects, Jiangnan Electric can review an existing motor nameplate, torque-speed requirement, mechanical drawing and servo-drive information before recommending an appropriate servo configuration.
Disclaimer
The information in this article is provided for general reference only. Product specifications, performance, configuration options and suitability must be evaluated in detail for the intended application and actual operating conditions. Before selecting, purchasing or using a product, please confirm the relevant details with Jiangnan Electric and refer to the applicable technical documentation and agreed specifications. This article does not replace product-specific instructions or a professional engineering assessment.